Assessment of Thermal Comfort: A Study at Closed and Ventilated Call Centre
Abstract
Problem statement: The aims of study were to investigate the effects of environmental factors including the human physiology and thermal comfort during the cycle of process works in workplace. Approach: The selected production line was handling the restoration of trouble report. The environment examined was the relative humidity (%), wind speed (m sec-1), illuminance (lux) and air temperature (°C) of the surrounding workstation area. The environmental factors were measured using thermal comfort apparatus, which is capable to measure simultaneously those mentioned environmental factors. The time series data of fluctuating level of factors were plotted to identify the significant changes of factors. Then the thermal comfort of the workers was assessed by using ISO Standard 7730 and thermal sensation scale by using Predicted Mean Vote (PMV). Further Predicted Percentage Dissatisfied (PPD) is used to estimate the thermal comfort satisfaction of the occupant. Finally the PMV were plotted to present the thermal comfort scenario of workers involved in related workstation. Results: The thermal comfort assessment of this workplace which is slightly warm following by thermal sensation and likely to be dissatisfied by the occupant. Conclusion: The result indicated that the activity level and clothing more influenced comfort to the occupants.
DOI: https://doi.org/10.3844/ajassp.2010.402.407
Copyright: © 2010 A. R. Ismail, N. Jusoh, N. K. Makhtar, J. S.M. Zakaria, M. K. Zainudin, Z. C. Omar and R. A. Ghani. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
- 3,799 Views
- 3,318 Downloads
- 8 Citations
Download
Keywords
- Thermal
- comfort
- close
- ventilated